论文部分内容阅读
比较了AT(Latex免疫凝聚比浊测定法)和RIA法(放射免疫测定法)检测新鲜的随机尿样微量白蛋白(mA),并评价其临床应用价值。健康对照组AT(-)(11例),尿白蛋白6.0±2.3mg/L糖尿病组AT(-)(61例),11.0±8.7mg/L;AT(+)组(13例),38.1±10.2mg/L。用RIA法测尿帆mA,以mA30mg/L作为分割线,AT与RIA法的一致率为89.2%,结果表明AT可以作为早期糖尿病肾病尿微量白蛋白监测的简便迅速的方法。
The AT (Latex Immunoagulant Turbidimetric Assay) and RIA (radioimmunoassay) were compared to measure the freshness of random urine microalbumin (mA), and its clinical value was evaluated. AT (-) in the healthy control group (n = 11), AT (-) in the diabetic group with 6.0 ± 2.3 mg / L urinary albumin, and n = 11.0 ± 8.7 mg / (13 cases), 38.1 ± 10.2 mg / L. The urinary mA was measured by RIA method. The mA30mg / L was used as the dividing line. The concordance rate between AT and RIA was 89.2%. The results showed that AT could be used as a simple and rapid method to monitor urinary albumin in diabetic nephropathy.