伊立替康单药二线治疗进展期结直肠癌的临床价值分析

来源 :中国实用医药 | 被引量 : 0次 | 上传用户:wuaiboer
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的分析研究伊立替康单药二线治疗进展期结直肠癌的临床价值。方法盲选本院收治的66例进展期结直肠癌患者,给予患者采用伊立替康单药二线治疗,分析评价其临床价值。结果 66例患者治疗后,部分缓解16例(24.2%),稳定34例(51.6%),进展16例(24.2%),有效率为24.2%,疾病控制率为75.8%。血液学毒性为Ⅰ度骨髓抑制以及Ⅱ度中性粒细胞减少症38例(57.6%),Ⅲ+Ⅳ度中性粒细胞减少症24例(36.4%);非血液学毒性为:Ⅰ+Ⅱ度恶心呕吐38例(57.6%),Ⅲ+Ⅳ度恶心呕吐5例(7.6%),Ⅰ+Ⅱ度迟发性腹泻24例(36.4%),Ⅲ+Ⅳ度迟发性腹泻4例(6.1%)。结论给予进展期结直肠癌患者采用伊立替康单药二线治疗,疗效满意,安全可靠,值得应用推广。 Objective To analyze the clinical value of irinotecan monotherapy second-line treatment of advanced colorectal cancer. Methods blind selection of 66 cases of patients with advanced colorectal cancer admitted to hospital with irinotecan monotherapy second-line treatment, analysis and evaluation of its clinical value. Results Sixty-six patients (24.2%) were relieved partially, 34 patients (51.6%) were stable and 16 patients (24.2%) were cured. The effective rate was 24.2% and the disease control rate was 75.8%. Hematological toxicity was grade Ⅰ myelosuppression and grade Ⅱ neutropenia in 38 cases (57.6%), grade Ⅲ + Ⅳ neutropenia in 24 cases (36.4%); non-hematological toxicity was: Ⅰ + Ⅱ (N = 37), nausea and vomiting in 38 cases (57.6%), grade Ⅲ + Ⅳ nausea and vomiting in 5 cases (7.6%), delayed diarrhea in 24 cases %). Conclusions The patients with advanced colorectal cancer were treated with irinotecan monotherapy second-line therapy, the results were satisfactory, safe and reliable, and should be applied and popularized.
其他文献
对商用BiCMOS模数转换器(ADC)AD678进行不同剂量率下电离辐射效应及室温退火特性的研究。结果表明,ADC的敏感参数在不同剂量率下的响应有差异;模拟电源电流和数字电源电流的
本文在分析数字化校园特征的基础上,重点研究了高校校园数字化进程对教学的影响,和在此背景下教师作用的新变化,探讨了适应校园数字化建设的高校教学管理。 Based on the an
通过对不同厚度样品的γ射线测量,得出波谱峰面积与样品厚度的关系,并通过相对测量和效率刻度测量方法,计算不同厚度样品在46.5、351.9、477.6、661.7 keV能量下的探测效率.
离子在样品内的能量岐离将改变中子深度分析(neutron depth profiling,NDP)的多道离子能谱分布.基于SRIM程序,分析了10B(n,α)7Li反应产生的四种离子穿过硅材料后的能最离散
In spite of the rapid developments in communication technologies over the past few decades,which include attractive features offered by the presently used 3G/4G
介绍了SAUNA惰性气体氙移动取样系统的组成和基本功能,684 h取样性能研究结果表明,该系统拆卸、组装方便,性能稳定,氙取样量的平均值为2.2 mL/d,具备连续多天高效取样的能力.
介绍了一种脉宽在0.45-8.5μs、幅度在100-300 V内可调,脉冲上升时间<30 ns的电源研制方案,阐述了电源的工作原理及调试过程.实验结果表明,设计的快脉冲电源稳定性高、电路简
介绍了3He半导体夹心谱仪的探头组件和电子学系统,开展了热中子调试,获得快中子临界装置上0.1-1.3 MeV的能谱数据.测量结果与6Li夹心谱仪在0.3-1.3 MeV范围非常符合,证明该谱
碳纳米管(NTs)易吸附环境中各种有毒金属离子,形成复合物,其生物效应和毒性有别于CNTs和金属离子单独作用及两重材料简单生物效应的叠加效果.阐述了金属离子在CNTs上吸附概况
2011年2月25日,第十一届中国房地产发展年会在北京国贸大酒店群贤宴会厅顺利举行。本次发展年会共邀请了逾两千名地产精英和专家学者前来参加。其中包括万科、远洋、中海、龙