我们遇到4例急性二氧化碳(CO_2)中毒的病例,1例当时死亡,3例经现场抢救生存,报告如下。病历资料患者男性,48岁,于1983年9月30日只身下井维修长期不用的深井水泵(电动)。20时许,他人发现昏倒在深井机台口,被救出井面时,面色青紫,四肢紫绀,瞳孔散大,呼吸、心跳均已停止,抢救无效死亡。余3例均为男性青年,当发现前者倒在井内时,即依次下井抢救,但都在入井7m左右突感头昏、胸闷,约10秒钟后,即失去知觉掉至井下机台上(机台离井面14m)。此时,在场的其他人员将鼓风机(功率为2瓩)接上约12m 长的胶管直接向井下吹风。10分钟
We encountered 4 cases of acute carbon dioxide (CO_2) poisoning cases, 1 died at the time, 3 survived by on-site rescue, the report is as follows. Medical records Patient Male, 48 years old, on September 30, 1983 alone under the well to repair long-term use of deep well pump (electric). 20 o’clock, others found collapsed in the deep machine Taiwan’s mouth was rescued from the well, the face bruising, cyanotic limbs, mydriasis, breathing, heartbeat have stopped, died of rescue ineffective. When the former fell into the well, the wells were salvaged in succession. However, all of them were suddenly dizzy and chest tightness about 7m into the well. After about 10 seconds, they lost consciousness to the underground machine Machine from the well surface 14m). At this point, other people in the presence of the blower (power 2 瓩) connected to about 12m long hose directly downhole hair. 10 minutes