Ergonovine stress echocardiography: Recent experience and safety in our centre

来源 :World Journal of Cardiology | 被引量 : 0次 | 上传用户:xianwolf
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
AIM:To study recent experience and safety of ergonovine stress echocardiography in our centre.METHODS:In this study we collected the clinical variables of patients referred since 2002 for ergonovine stress echocardiography,in addition to indications,the results of this test,complications,blood pressure and heart rate values during the test and the number and results of tests requested before this technique.RESULTS:We performed 40 tests in 38 patients,2 tests were carried out to verify therapy efficacy.The prevalence of classic cardiovascular risk factors was low and the most frequent indication was chest pain (57.5%).Coronary angiography was performed in 32 patients,and showed normal coronary arteries in 27 patients and non-significant stenosis in 5 cases.In 16 patients,coronary angiography was carried out after a positive or inconclusive ischemia test.Another 6 patients had a normal stress test(5 exercise electrocardiography tests and 1 nuclear imaging test).Of the 40 ergonovine stress echocardiography tests,6 were positive(4 in the right coronary artery territory and 2 in the circumflex coronary artery territory),all of them by echocardiographic criteria,and by electrocardiographic criteria in only 3(50%).The presence of non-significant coronary artery stenosis was more frequent in patients with positive ergonovine stress echocardiography(50%vs 6%,P =0.038),and were related to ischemic territory.During the maximum stress stage,there was a higher systolic(130.26±19.17 mmHg vs 136.58±27.27 mmHg,95%CI:-12.77 to 0.14 mmHg,P=0.055)and diastolic blood pressure(77.89±13.49 mmHg vs 83.95± 15.73 mmHg,95%CI:-10.41 to-1.69 mmHg,P=0.008) than at the baseline stage,and the same was registered with heart rate(73±10.96 beats/minvs 79.79± 11.72 beats/min,95%CI:-9.46 to-4.11 beats/min,P <0.01).Nevertheless,there were only 2 hypertensive reactions during the last stage,which did not force a premature end to the test,without sustained tachy or bradyarrhythmias,and the technique was well tolerated in 58%of cases.A unique complication(2.5%)of this test was a prolonged vasospasm with a slight increase in necrosis biomarkers,however,this was without repercussion.CONCLUSION:Ergonovine stress echocardiography can be performed with safety,is well tolerated in the majority of cases,and is useful for determining the ischemia mechanism in selected cases. AIM: To study recent experience and safety of ergonovine stress echocardiography in our center. METHODS: In this study we collected the clinical variables of patient referred since 2002 for ergonovine stress echocardiography, in addition to indications, the results of this test, complications, blood pressure and heart rate values ​​during the test and the number and results of tests requested before this technique.RESULTS: We performed 40 tests in 38 patients, 2 tests were carried out to verify therapy efficacy. prevalence of classic cardiovascular risk factors was low and the most frequent indication was chest pain (57.5%). Coronary angiography was performed in 32 patients, and showed normal coronary arteries in 27 patients and non-significant stenosis in 5 cases. 16 patients, coronary angiography was carried out after a positive or inconclusive ischemia test. Another 6 patients had a normal stress test (5 exercise electrocardiography tests and 1 nuclear imaging test) .Of the 40 ergonovine stres The echocardiography tests, 6 were positive (4 in the right coronary artery territory and 2 in the circumflex coronary artery territory), all of them by echocardiographic criteria, and by electrocardiographic criteria in only 3 (50%). The presence of non-significant coronary artery stenosis was more frequent in patients with positive ergonovine stress echocardiography (50% vs 6%, P = 0.038), and were related to ischemic territory. During the maximum stress stage, there was a higher systolic (130.26 ± 19.17 mmHg vs 136.58 ± 27.27 mmHg, 95% CI: -12.77 to 0.14 mmHg, P = 0.055) and diastolic blood pressure (77.89 ± 13.49 mmHg vs. 83.95 ± 15.73 mmHg, 95% CI: -10.41 to-1.69 mmHg, P = 0.008) than at the baseline stage, and the same was registered with heart rate (73 ± 10.96 beats / min vs 79.79 ± 11.72 beats / min, 95% CI: -9.46 to-4.11 beats / min, P <0.01) hypertensive reactions during the last stage, which did not force a premature end to the test, without sustained tachy or bradyarrhythmias, and the techniqu e waswell tolerated in 58% of cases. A unique complication (2.5%) of this test was a prolonged vasospasm with a slight increase in necrosis biomarkers, however, this was without repercussion. CONCLUSION: Ergonovine stress echocardiography can be performed with safety, is well tolerated in the majority of cases, and is useful for determining the ischemia mechanism in selected cases.
其他文献
对临床诊断为心脑合病患者采用中西医结合治疗1个疗程,运用中医的异病同治原则,以“痰瘀”论治心脑合病,将化痰祛瘀法贯穿治疗始终,并根据患者临床症状和理化检查判定其临床
基于Q690高强钢的焊接工艺,通过SYSWELD对Q690钢MIG对接焊进行了数值模拟,得出了瞬态温度场分布图和特征点的热循环曲线,验证了有限元软件SYSWELD模拟的准确性。在此基础上得
近年来,随着我国工农业生产的迅速发展,稀土——镁球墨铸铁已代替了大量贵重的钢材而得到广泛的应用。据资料报道,用钇基稀土作制造墨铸铁的球化剂时,不需用金属镁且性能较
气流粉碎介乙醛晶粒适用于人工影响天气的飞机播撒作业。实验结果指出,气流粉碎的介乙醛晶粒比未粉碎的可提高成核率10~2—10~3倍。在-2——20℃温度范围,气流粉碎的介乙醛晶
在中纪委及国务院有关部门的推动下,经过几年的探索,会计委派制试点工作已在全国多个省、市稳步推开,并取得了很大成效。从已开展会计委派制试点工作的浙江、江苏、黑龙江、
请下载后查看,本文暂不支持在线获取查看简介。 Please download to view, this article does not support online access to view profile.
甲基乙烯基酮(以下简写为MVK)的测定,前人提供了一些方法,丙烯腈中微量MVK的极谱测定则未见有文章报导;本文提供的方法,基底溶液由试样量的1.5倍的95%乙醇和PH为2.4的邻苯二
本文报导了用Ni——二甲酚澄——溴化十六烷基三甲基铵三元络合物快速测定镍的反应条件和络合物的组成,方法具有灵敏度高,选择性好等优点,最大的特点是显色较迅速,颜色稳定。
1979年9月5日在北京科学会堂聚集了中国和美国的高分子科学家,开始了为期五天的中美双边高分子化学和物理讨论会。这次双边学术讨论会是根据中国科协和美国美中学术交流委员
80年代以来,随着我国“对内搞活、对外开放”政策的实施,边境地区与周边国家和地区的易货贸易得到了迅速发展。进入90年代以后,随着我国证券市场的发展、包括资产置换、股权