本文结合现场实践,分析了上汽厂生产的凝汽式汽轮机组全液压调速系统带负荷工况下大幅度晃动的原因,并介绍了消除措施。该系统所存在的这一缺陷,与调速汽门重叠度、二次油压稳定性、错油门过封度及其结构型式等因素有关,而错油门过封度偏小以及结构不够合理是造成大幅度晃动的主要原因。采取相应的改进措施,尤其是加大错油门过封度并采用新型的斜切梯形缺口圆弧槽式错油门后,这样既消除调速系统大幅度晃动,又使动态能无明显影响的目的。
In this paper, combined with the field practice, the reasons for the drastic shaking of full hydraulic speed control system of condensing steam turbine unit under load are analyzed and the elimination measures are introduced. The system exists in this defect, and speed governor valve overlap, the second oil pressure stability, the wrong throttle over the degree and structure of its type and other factors, and the wrong gate over-size is too small and the structure is not reasonable The main reason for the drastic shake. Take appropriate improvement measures, especially to increase the fault gate over-seal degree and the use of a new type of trapezoidal notch arc slot-type misfirled, this will not only eliminate a large speed control system shaking, but also the dynamic effect of no significant effect .