本文堤出一种连续式非线性A/D转换器。其电路简单,线性比精度较高,用于铂 电阻温度传感器.在-200℃到 +650℃的全温度范围内线性化误差为0.058%. 按上述原理.采用 CMOS大规模集成电路 A/D转换器研制的铂电阻数字温度计, 在上述温度范围内.实测精度为0.12%. 本文论述了电路最佳参数I.K的选泽方法.给出采用小型计算帆(PC-1500) 求最佳参数 I.K的两个实用程序。可根据要求,在任意温度范围内.求出最佳的 I.K值和与之对应的误差.本文还提出进一步提高线性比精度的方法.以扩大应用 范围.
This article embankment out of a continuous non-linear A / D converter. The circuit is simple, high linear accuracy, for platinum resistance temperature sensor. The linearization error was 0.058% over the full temperature range of -200 ° C to + 650 ° C. According to the above principle. The use of CMOS LSI A / D converter developed platinum resistance digital thermometer, in the above temperature range. The measured accuracy is 0.12%. This article discusses the best circuit parameters I. K’s election Ze method. The optimal parameter I is given by using small calculation sail (PC-1500). K’s two utilities. Available on request, in any temperature range. Find the best I. K value and the corresponding error. This paper also proposed to further improve the accuracy of linear ratio method. To expand the scope of application.