我厂φ600合成塔使用了镍铬-镍硅多点式热电偶测温。有一次,在生产正常的情况下,发现XWC-300型长图记录仪表所记录的曲线中,有一测温点的温度示值呈下降趋势(下降到比原实际操作温度低120℃左右)。我们检查记录仪表、一次元件及线路均无问题。再仔细检查热电偶的外套管,结果发现其上有一破裂处,该处位于一测温点附近,所测的是渗透了气体的温度值,它比实际操作温度值低,
I plant φ600 synthesis of nickel-chromium - nickel-silicon multi-point thermocouple temperature. Once, when the production was normal, it was found that the temperature recorded by the XWC-300 chart recorder showed a downward trend (down to about 120 ℃ lower than the actual operating temperature). We check the recording instrument, a component and the line is no problem. Carefully check the thermocouple jacket and found that there is a rupture, which is located near a temperature measurement point, the measured value is the infiltration of gas temperature, which is lower than the actual operating temperature,