【摘 要】
:
Spectral data across energy bins are highly correlated but the signal to noise ratio is generally poor for each energy bin due to the narrow bin width and r
【出 处】
:
Computational Biomedical Imaging Workshop(2015计算生物医学成像研讨会)
论文部分内容阅读
Spectral data across energy bins are highly correlated but the signal to noise ratio is generally poor for each energy bin due to the narrow bin width and resultant quantum noise.To address this problem,in this paper we propose a spectral CT reconstruction approach that simultaneously reconstructs x-ray attenuation coefficients in all the energy bins,aided by intra-image sparsity and inter-image similarity.In addition,a sparsifying transform in terms of total variation(TV)and spectral means(SM)are respectively utilized for similarity measurement.To facilitate the quantification of the similarity,we design a linear mapping function to minimalize image differences between different energy bins.Experimental results show that the proposed algorithms qualitatively and quantitatively outperform existing iterative algorithms for spectral CT reconstruction.
其他文献
复杂结构件在X射线三维CT成像时,由于射线透射方向上有效透照厚度差异大、探测器成像系统动态范围受限,常用固定能量模式的X射线成像系统无法获取结构件的完整信息,影响CT重
In this talk,I will propose a convex model for simultaneous image restoration and segmentation based on global TV.We adopt the widely used ADMM to solve the
Parameter mapping is a powerful noninvasive technique providing quantitative biological information of the inherent tissue properties.In this talk,we will i
To improve the low-dose CT(LDCT)imaging quality,we proposed a new processing approach based on the morphological component analysis(MCA),with the integratio
I will start with a brief review of existing models(both classical and recent)for solving ill-posed linear inverse problems,that include wavelet frame based
In this talk,we focus on the challenging problem of removing the spatially varying out-of-focus blur from a single natural image.We first propose an effecti
Images by reflection imaging can be well approximated by piecewise constant functions.Thus total variation is an essential tool to regularize this kind of i
In some practical applications,restricted by scanning environment or scanned object,the projection data obtained from CT imaging system is incomplete,which
In this paper,aboundary-type meshless numerical scheme,based on the singular boundary method(SBM),is proposed to efficiently analyze the two-dimensional Sig
Based on the recently developed MFS-based particular solution for two-dimensional problems in isotropic linear thermoelastic materials [1],we investigate th