Background,Motivation and Objective Ultrasound bidirectional axial transmission(BDAT) has been originally developed to measure the speed of sound of the first arriving signal(VFAS) in the cortex of lo
【机 构】
:
BCRT,Charité Universit(a)tsmedizin Berlin,Berlin,Germany
论文部分内容阅读
Background,Motivation and Objective Ultrasound bidirectional axial transmission(BDAT) has been originally developed to measure the speed of sound of the first arriving signal(VFAS) in the cortex of long bones.This approach was tested in a clinical study at the distal radius of postmenopausal subjects(Talmant,UMB 35 912-919-2009).
其他文献
Background,Motivation and Objective Hypertension affects 1 in 3 American adults and is the single largest contributor to death world-wide.Approximately 25-35 %of people with hypertension cannot adequ
Background,Motivation and Objective Tightening and contracture of dense fibrous tissues including tendons and ligaments are debilitating conditions frequently encountered in clinical practice.
Background,Motivation and Objective In the field of therapeutic ultrasound,a tissue mimicking phantom is essential for dosimetry and standardization.A bovine serum albumin(BSA) based gel phantom is wi
Background,Motivation and Objective This article illustrates the preparation of perfused Thiel swine kidney which is used for the image-guided FUS therapy on this perfused phantom to simulate the infl
Background,Motivation and Objective Burst-mode focused ultrasound(FUS) exposure with the presence of microbubbles has shown its promise in temporally and targeted open the blood-brain barrier(BBB),and
Background,Motivation and Objective Histotripsy is a non-invasive,controllable and fine focused ultrasound surgery method using microsecond or millisecond pulse with peak negative pressure larger than
Background,Motivation and Objective Acoustic cavitation bubbles can accelerate therapeutic effect in high-intensity focused ultrasound(HIFU) treatments.In our previous study,it was demonstrated that s
Background, Motivation and Objective The fundamental ultrasonic guided modes (UGM) are consistently observed in long bones in vitro and in vivo. The responses of UGM to the changes of cortical thickne
Background,Motivation and Objective Quantitative ultrasonic characterization of cortical bone based on the analysis of the waveguide response of the cortical shell of long bones has been reported.Howe
Background,Motivation and Objective BUA(Broadband Ultrasonic Attenuation) is an accepted indicator of trabecular bone status.To examine the bones lying deep in the human body one can use scattered wav