Evaluation of interactions between proteins and Fe3O4 nanoparticles by pulsed streaming potential in

来源 :第八届全国微全分析系统学术会议、第三届全国微纳尺度生物分离分析学术会议暨第五届国际微化学与微系统学术会议 | 被引量 : 0次 | 上传用户:datoufangyuan
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Magnetic nanoparticles have attracted much attention in biomedical areas due to their excellent biological compatibility,easy coupling with other molecules and great manipulability through magnetic fields.Interaction between the nanoparticles and the biomolecules has been a hot topic and deserves great efforts for better application of these materials [1-2].In our work,the interaction of citric acid dispersed Fe3O4 nanoparticles (Fe3O4-NPs) with three common proteins,bovine serum albumin(BSA) 、bovine hemoglobin(BHB)、trypsin(TRY) was evaluated by pulsed streaming potential over fused silica capillaries.The evaluation relied on the change of streaming potential caused by the flushing of solutions of proteins,nanoparticles and their mixtures.The interaction of a protein with the nanoparticles was deducted through the streaming potential differences obtained with pure protein solutions and the mixtures of proteins and nanoparticles.The results demonstrated that the presence of Fe3O4-NPs significantly changed the streaming potential values,which indicated possible interactions between Fe3O4-NPs and the proteins (Figure 1,Figure 2).The acidity of the solution exhibited profound influence on the process and the highest changes of streaming potential were obtained at pH of 8.2,8.3 and 5.6 for BSA,BHB and TRY,respectively.Similar results were obtained within microchannels of cyclic olefin copolymer (COC) chips.Based on these results,it can be concluded that pulsed streaming potential might be a way to study the interaction between proteins and nanoparticles.
其他文献
An on-site ultrasensitive sandwich immunoassay was developed for the detection of ractopamine (RAC) using magnetic calixarene as capture probe and Antibody (Ab)-Envision polymer-invertase on Au NPs (E
会议
以铋做内标,结合丝网印刷电极与微型化的电化学检测系统,采用方波溶出伏安法建立了一种警报型即时检测方法,将其用于自来水体中铅含量是否超标的判断。加入一定量Bi3+标准溶液后,测定含10 ppbPb2+标准溶液的IPb/IBi并计算得出阈值。测定自来水样的IPb/IBi后,与阈值对比给出Yes/No判断结果,通过ICP-MS验证方法的有效性。作为一种简捷、快速和便携的检测平台,这种方法无需测出Pb2+
环境雌激素主要指那些进入动物或人体后,能对机体内正常内分泌物质的合成、释放、运转、代谢以及结合等产生干扰,激活或抑制内分泌系统功能,从而破坏其维持机体稳定性和调控作用的外源性化合物.研究表明,一些人工合成的化学物质也具有类似雌激素的生物效应, 它们可干扰鸟类、爬行类以及哺乳类野生动物或实验动物正常的内分泌功能,改变动物在发育和成年阶段胞内信号过程[1], 并由此造成动物的雌雄性别的改变以及畸形等病
会议
In recent years,as the integrated circuit (IC) technologies and Micro/Nano-Electro-Mechanical System (M/NEMS) develop rapidly,more and more micro/nano devices are fabricated or commercialized.1,2 But
会议
We present a simple technique to real-time screening two single-cells signal interactions on our unique microfluidic chip,which is potentially useful for single-cell-based research.The interactions be
Nanometer scale sorting filters of high chemical selectivity and high flux are strongly desired for chemical separation1,drug delivery2 and waste water remediation3.In recent years,there has been trem
Due to the advantages of rapid response and the programmability of droplet movements,electrowetting on dielectric (EOWD) has become a major platform for driving droplets in microfluidic systems [1].Fo
The U.S.Geological Survey found that there is 96.5% water in the oceans and sea,1.7% in the ice caps,1% in brackish water,and only 0.8% fresh water [1].1.2 billion people lack access to safe drinking
Circulating tumor cells (CTCs) are viable cells found in blood of cancer patients; isolation of these cells from blood sample is significant in understanding the cancer metastasis through a non-invasi
We developed streaming potential/current measurement system for investigation of liquid property in 101-103 nm space (extended-nano space) [1].Using streaming potential/current system,higher electric