Evaluation of various fiducial markers for real time tumor tracking of Vero system

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:jiangchong122
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose To evaluate feasibility and accuracy of various fiducial markers when using a gimbaled linac of Vero SBRT system for real time tumor tracking(RTTT).Methods and Materials We used various fiducial markers consisting of titanium,stainless steel,iron,copper,silver,gold,and tantalum for their potential use as tracking markers in RTTT.All markers,1 mm in diameter and 5 mm in length,were located on a 2-dimensional moving phantom(Brainlab,Germany)producing sinusoidal motion with frequencies up to 30 breaths per minute(bpm).CT scans for the phantom were acquired and orthogonal kV images were taken for detection of fiducial markers.For measurement of accuracy of target centers,dose profiles were measured using GAFCHROMIC EBT2 films.The gantry and o-ring angles for this experiment were combined as 0° and 45° for synchronous motion of pan/tilt.Results Fiducial markers having atomic number less than 29 such as titanium,stainless steel,and iron were not detected on kV images for RTTT system.Other fiducial markers having atomic number higher than 29(copper,silver,gold,and tantalum)were precisely detected on orthogonal kV images.Regarding fiducial markers detected in the angles of gantry 0(!)(AE)/o-ring 0(!)(AE)(G0/R0),the deviation between static field and RTTT field was within 0.78 mm at pan/tilt motion.In the angles of gantry 0(!)(AE)/o-ring 45(!)(AE)(G0/R45),the maximal deviation was 0.89 mm.Conclusions The markers consisting of high atomic number material(>29)were feasible as fiducial markers for RTTT using a gimbaled linac of Vero system with high geometric accuracy.
其他文献
  Purpose:The efficacy of spatially fractionated(GRID)radiotherapy for treating bulky tumors has been recognized and demonstrated.GRID therapy might improve t
会议
  Purpose:PET visualization method is routinely used in clinical practice,however,it has high interobserver variations and relies on the experience of nuclear
会议
会议
  Purpose:A novel breathing guidance method by combining the personalized audio-visual biofeedback(BFB)system,the breath hold(BH)method,and the synchrotron-ba
会议
  Fluorescence diffuse optical tomography(FDOT)is an emerging cost-effective modality for small animal imaging.It allows one to obtain quantitative functional
会议
会议
  Purpose:If rectal balloon were not used in rectum cancer treatment,there is a lack of reproducibility of rectum shape on each treatment and irregularly inse
会议
会议
  1.Introduction: This research applies the Monte Carlo simulation method EGSnrc Electron Gamma Shower(EGSnrc)Code with two code is dedicated: BEAMnrc code is
会议
  Objective The paper is to perfect complete the QA process by developing of the method used to fast verify the center position of body patient which are trea
会议