Motion Detection and Correction in PET/CT Brain Imaging

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:ntyiran
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:Head motion in PET/CT leads to artifacts due to the mismatch of PET and CT images.This work aims at reducing motion artifacts in PET image reconstruction.Methods:The correction method for head motion is based on the facts that the motion is rigid,irregular and within a short time.Our method contains three important steps.Firstly,the acquired data is cut into short time frames(such as 10s per frame)and reconstructed with a coarse image matrix.Through dynamic reconstruction,we could find out the time intervals during which motion happens.The listmode data acquired in these time intervals would not be used.Secondly,one of the frames is selected as the reference.To simplify the problem,the three-dimensional motion is decomposed into three two-dimensional motions.That is,the motion in tangential,sagittal and coronal directions.The two-dimensional registration is achieved by maximization of the mutual information of two reconstructed frames.Additionally,to ensure accuracy of the estimated correction parameters,the registration is repeatedly performed at different image slices from the same frame and their weighted average is used as the final result.Thirdly,since each LOR is uniquely determined by four parameters(s,φ,z,θ),we generate four lookup tables,each of which corrects one parameter during the image reconstruction process.Results:To demonstrate the feasibility and the accuracy,the performance of our method was verified by two clinical datasets both of which had obvious head motion.Results showed that the proposed method could well detect the time intervals when the motion happened and correct the motion blurring.Conclusions:The correction method could detect the time intervals when the motion happened and correct the motion blurring.It reduces the motion artifacts in PET image reconstruction.
其他文献
  Purpose: Propose a novel PET image reconstruction method to improve image resolution and noise property simultaneously in PET/CT studies.Method: The PET/CT
会议
  Nuclear magnetic resonance(NMR)image is often used in medical diagnosis.Andimage super-resolution(SR)is the important steps in the NMR image analysis,which
会议
  Purpose: X-ray scatter poses a significant limitation to image quality in cone-beam CT(CBCT),as well as beam hardening,resulting in image artifacts,contrast
会议
  Automatic lung tumor localization plays a significant supporting role on diagnosing and treatment of lung cancer.It could be able to avoid clinicians making
会议
  Purpose: To improve the image reconstruction quality of multi-energy photon counting X-CT based on prior image constrained compressed sensing by evaluation
会议
  Purpose: Segmental scanning protocol of Multi-energy computed tomography(MECT)is an easy-to-implement and no-extra dose induced way realized in conventiaona
会议
  Objective:Evaluated the speed and accuracy of GPU-based collapsed cone dose calculation.Methods:Ten Head and Neck patients and Ten cervical carcinoma patien
会议
会议
  Objective:To investigate the treatment plan quality between two treatment planning systems(TPS)for volumetric modulated Arc therapy(VMAT).Materials and Meth
会议
  Purpose: The application of limited-angle computed tomography(CT)has great expectation in some clinical circumstance such as dental CT imaging.Existing iter