The Comparative Study of Dual-source CT and Ultrasound Cardiography on the assessment of the Pulmona

来源 :全军第十六届放射医学大会 | 被引量 : 0次 | 上传用户:sebeer
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective To investigate the clinical value and accuracy of DSCT in the assessment of the pulmonary arteries in patients with complex congenital heart disease.Materitals and methods DSCT and echocardiography was performed respectively in patients with complex congenital heart disease.49 patients were collected, whose pulmonary arteries were abnormal verified by operation.7 aspects were concerned,including pulmonary artery trunk, left and right pulmonary arteries, the confluence of pulmonary, stenosis of pulmonary, patent ductus arteriosus and major aortopulmonary collateral arteries.The results were compared with each other to evaluate the ability of manifestation of the pulmonary arteries and reveal their relevance.Result The pulmonary arteries could be clearly observed from original images and multi-planar reconstruction images at different angles.DSCT was superior to echocardiography for the non-invasive assessment of pulmonary artery anatomy(overall test parameters of DSCT: sensitivity 93%, specificity 97%,PPV 99%, NPV 83%; overall test parameters of echocardiography: sensitivity 79%, specificity 80%, PPV 92%,NPV 57%).A high correlation was obtained from measurements (coefficient of correlation: main pulmonary artery 0.96, left pulmonary artery 0.97, right pulmonary artery 0.92).Conclusion Disregarding heart rate,DSCT is superior to echocardiography for the assessment of pulmonary artery anatomy.
其他文献
目的:评价多层螺旋CT扫描技术对椎弓崩裂性滑脱的诊断价值.方法:对53例腰椎滑脱并椎弓崩裂的多层螺旋CT表现进行回顾性分析.结果:腰椎椎弓峡部崩裂多层螺旋CT表现均可见椎弓宽窄不一的低密度裂隙,边缘不规则,椎管骨性面表现环状骨质不连续,椎管横径变小,前后径变长.结论:应用多层螺旋CT诊断椎弓崩裂性滑脱可大大提高诊断的准确性和及时性,为正确治疗腰椎滑脱提供了有力依据.
Objective To explore the CT performance ofintrahepatic focal leisions in the context of fatty liver.Methods To retrospective analysis the morphology, density and distribution of 23 cases of fatty live
Objective To explore differential diagnosis of hepatic nodules from benign and malignant lesions by DSCT perfusion.Methods 20 patients without hepatic diseases and 49 hepatic nodules confirmed by path
Purpose: By researching liver tumor model(Wister rat liver tissues) in vitro high-resolution magic angle spinning 1H MRS analysis, in order to get metabolism informations of liver tumor and normal tis
目的:分析肾盂移行上皮细胞癌CT表现.方法:回顾性总结分析经病理证实的13例肾盂移行上皮细胞癌的CT表现.结果:13例中男9例,女4例.病灶位于左肾5例,右肾8例;肾盂内7例,肾盂输尿管开口处6例.肿瘤直径0.5-4.1cm,平均2.3cm.10例表现为肾盂内息肉状肿物,3例表现为肾盂壁小结节样增厚.灌注减低10例,3例灌注无明显异常.增强扫描动脉期轻度强化,实质期进一步强化10例;三期均轻度强化
目的:LiF∶Mg,Cu,P热释光探测器是辐射防护和个人剂量监测等领域应用最为广泛的辐射剂量探测器,探测器使用过程中的退火、冷却、辐照和测量等环节都将影响到剂量检测的准确性。本实验旨在探究热释光探测器的两种退火温度(240℃、250℃),在不同的冷却方式情况下对探测器的分散性、灵敏度及发光曲线的影响,从而获得最优化退火温度和冷却条件。
会议
目的:评价MRI低信号分隔征在乳腺纤维腺瘤诊断中的价值.方法:回顾性分析经手术病理证实的52例共54个纤维腺瘤的MRI表现特点,分析低信号分隔征的鉴别诊断价值.结果:54个纤维腺瘤中,37个纤维腺瘤在MRI可观察到低信号分隔,发生率为69% (37/54);其中29个病灶分隔厚度小于2mm,8个病灶厚度大于2mm.37个病灶低信号分隔在T1WI脂肪抑制序列均观察不清,33个病灶在T2WI脂肪抑制序
BACKGROUND: In patients with Kawasaki disease (KD), it is necessary for evaluating the risk stratification and therapeutic management in the distribution and size of coronary artery aneurysms (CAA).Al
会议
Objective: To explore the clinical application value of dual-energy imaging with Dual-source CT(2008G Siemens Somatom Definition) for head and cervical vessel diseases.Methods: The imaging data underw
Objective To show the improved diagnostic image quality of dual-energy myocardial scan mode compared with coronary CTA scan mode with Dual-Source CT.Methods We performed a retrospective analysis of 10