Monte Carlo study of positron emitter production for in-beam PET imaging during carbon-ion radiother

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:wstpxx
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:Carbon-ion therapy can get better dose distribution in comparison with conventional radiotherapy owing to its Bragg Peak.But the beam range verification remained intractable.Positron emission tomography(PET)is potentially a good resolution,especially for in-beam range verification.This method is based on the detection of β+emitted by 11C,15O,10C produced during carbon-ion therapy,thus β+production is important to PET image quality.This study is to calculate the positron emitter production in clinical carbon-ion radiotherapy and give a preliminary result.Methods:For PET imageing during carbon-ion therapy,we use two plate(usually fixed on the gantry)detector heads to avoid the interference with the treatment beamline.The PET head are made of 3*5 detector modules,and each module includes a 25*25 array.For a single array,it consists of a 2mm*2mm*18mm LYSO pixels.A PMMA phantom of 15cm*15cm*15cm was irradiated by a 200 MeV and 250 MeV 12C beamline with 8mm FWHM and 10e6 pps separately.GATE,a monte carlo software based on GEANT4,is used for PET simulation Results:The yield result shows 11C is the most important nuclei contributing to the total positron production,with 9.63%and 12.85%for the simulated beam energy.The production of 10C and 15O are much lower,with about 1.5%in total.As for the simulated beam,we can get larger proportion of positron emitters using higher beam energy.Conclusions:In this study,we simulated a dual-plate PET scanner used in carbon-ion radiotherapy and got the positron emitter yields produced by different beam energy.The result shows the feasibility that PET could be used in carbon-ion radiotherapy for in-beam verification.The future work is to take more detailed analysis using real human phantom.
其他文献
Purpose Golden ratio based k-space trajectories [1] are widely used in dynamic MRI because it providesapproximate uniform k-space distribution.However,rapidlyswitching gradient induced eddy current,wh
Purpose:Spectral computed tomography(CT) is known as a promising technique for obtaining enhancedimage with contrast agent.K-edge imaging is a useful method to distinguish different materials in spect
会议
Medical image segmentation is very important part of medical image processing.The accuracy of image segmentation effect the image feature extraction,classification and three-dimensional reconstruction
Backgrounds: Owing to unique radiological physics properties associated with the Bragg peak,proton and heavy ion therapies are potentially advantageous than the x-ray photon based external beam therap
Purpose: The accuracy of Ir-192 source positions and dwell times has a direct impact on the safe delivery of HDR brachytherapy treatment.Verification of actual dose delivery to the target volume and n
This article presents a research approach and implementation criterion on the construction of regional integrative radiotherapy information system(RTIS)based on the technical framework and profiles of
Purpose:In three dimensional(3D) scanned carbon ion radiotherapy,smaller beam spots are desired owing to their sharper lateral profiles,which definitely reduce the harm to healthy tissues and the orga
Purpose:To propose a comfortable,harmless and stable method to guide the hypnosis for the control of respiratory motion during radiotherapy.Methods:The virtual reality(VR)technology was applied in the
Objective.To demonstrate the medical physics activities in treatment of carcinoma cervix in B.P.Koirala Memorial Cancer Hospital(BPKMCH),Bharatpur,Nepal.Methods:Mega voltage external beam radiation th
Objective:hippocampus-sparing during whole brain radiotherapy poses important challenges with hippocampus contouring and treating plan.we use Linear accelerator-intensity modulated radiotherapy(IMRT)t